Provide reliable prime, standby, or emergency electricity for commercial, industrial, mining, construction, healthcare, education, hospitality, and remote-site applications with the Pulita New Energy PLD-3GF Diesel Generator Set.
The generator range may be configured from approximately 8kW to 1200kW with multiple diesel-engine, alternator, controller, voltage, frequency, enclosure, and automatic-transfer options. Available structures include open-frame, silent-canopy, super-silent, trailer-mounted, and containerized systems.
Every power configuration should be listed separately with its exact engine, alternator, current, dimensions, weight, fuel consumption, runtime, noise level, and final price.
Industrial diesel generator range
Available outputs from approximately 8kW to 1200kW
Prime or standby power capability
Multiple diesel-engine brand options
Brushless alternator options
50Hz or 60Hz configurations
230V/400V standard output
Custom regional voltage options
Three-phase, four-wire electrical connection
Automatic PLC control panel
Auto-start capability
Optional automatic transfer switch
Eight-hour base fuel-tank configuration
Open, silent, trailer, and container formats
12-month or 1500-hour warranty
Brand: Pulita New Energy
Model Series: PLD-3GF
Product Type: Industrial Diesel Generator Set
Power Range: Approximately 8kW / 10kVA to 1200kW / 1500kVA
Prime Power: Confirm for Selected Model
Standby Power: Confirm for Selected Model
Engine Brand Options: Cummins, Perkins, Deutz, Weichai, Ricardo, or Yuchai, subject to availability
Engine Model: Confirm for Selected Configuration
Cooling System: Confirm as Air Cooled or Water Cooled
Alternator Type: Brushless
Alternator Brand Options: Stamford, Faraday, Leroy-Somer, Marathon, Lingyu, or Equivalent
Controller Type: Automatic PLC Controller
Controller Options: SmartGen 6110, DSE7320, Deep Sea, or Equivalent
Standard Rated Voltage: 230V / 400V
Alternative Voltage Options: 110V, 220V, 230V, 380V, 400V, or Custom
Phase: Three Phase
Connection: Three Phase, Four Wire
Frequency: 50Hz or 60Hz
Engine Speed: 1500 RPM at 50Hz or 1800 RPM at 60Hz
Rated Current Range: Approximately 14.4A to 2700A, depending on configuration
Starting System: 24V DC Electric Start
Automatic Start: Available
ATS: Optional
Fuel-Tank Runtime: Approximately 8 Hours at a Specified Load
Structure Options: Open Frame, Silent Canopy, Super-Silent Canopy, Trailer, or Container
Listed Noise Level: Approximately 70–75 dBA, subject to enclosure and test conditions
Listed Weight: Approximately 780 kg, subject to selected model
Colour: Customizable
Warranty: 12 Months or 1500 Operating Hours, whichever occurs first
Certifications: CE and ISO, subject to valid documentation
Country of Origin: Shandong, China
The PLD-3GF series may be available in several power ratings, including smaller commercial units and large industrial systems.
The supplier references configurations such as:
8kW / 10kVA
4.5kVA
15kVA
75kVA
Higher-capacity models up to 1200kW / 1500kVA
Each generator should have its own accurate listing containing:
Prime power
Standby power
Rated voltage
Rated current
Phase
Power factor
Engine model
Alternator model
Dimensions
Weight
Fuel consumption
Fuel-tank capacity
Runtime
Noise level
Final price
Depending on the selected power rating, the generator may be supplied with an engine from:
Cummins
Perkins
Deutz
Weichai
Ricardo
Yuchai
The selected engine can affect power output, fuel efficiency, physical dimensions, service requirements, and spare-parts availability.
Before publishing, confirm:
Exact engine brand
Engine model
Cylinder count
Displacement
Aspiration type
Rated mechanical output
Cooling method
Fuel consumption
Oil capacity
Coolant capacity
Applicable emissions standard
The general specifications list air cooling, but several larger diesel-engine options may use water cooling.
The final listing should clearly identify whether the selected generator is:
Air cooled
Water cooled
Radiator cooled
Remote-radiator configured
Do not apply one cooling specification to the full 8kW–1200kW range.
The PLD-3GF series may be supplied with a brushless alternator from:
Stamford
Faraday
Leroy-Somer
Marathon
Lingyu
Another approved equivalent brand
Before publication, confirm:
Alternator brand and model
Rated kVA
Winding material
Insulation class
Protection rating
Excitation system
Automatic voltage regulator
Voltage-regulation accuracy
Alternator efficiency
The standard reference configuration is listed as 230V/400V with three-phase, four-wire output.
Other possible voltages include:
110V
220V
230V
380V
400V
Custom regional voltages
Available frequency configurations are:
50Hz: Typically 1500 RPM
60Hz: Typically 1800 RPM
Each version should clearly state voltage, phase, frequency, rated current, power factor, and terminal arrangement.
Depending on the selected configuration, the generator may use:
SmartGen 6110
DSE7320
Deep Sea controller
Another compatible PLC controller
The control panel may monitor:
Output voltage
Output current
Frequency
Engine speed
Oil pressure
Coolant temperature
Starter-battery voltage
Operating hours
Alarm conditions
Shutdown status
Confirm the controller model before advertising remote monitoring, synchronization, or communication functions.
An optional ATS may detect a mains failure, start the generator, and transfer the connected electrical load.
Confirm whether the ATS is:
Included in the price
Sold separately
Integrated into the generator
Supplied as an external cabinet
Rated for the selected current
Compatible with the selected phase and voltage
The base fuel tank is described as supporting approximately eight hours of operation.
Actual runtime depends on:
Generator load
Tank capacity
Engine efficiency
Fuel quality
Ambient temperature
Maintenance condition
Selected engine model
Fuel consumption at 25%, 50%, 75%, and 100% load should be confirmed before publishing.
Provides direct access for service and installation. It requires a properly designed generator room or weather-protected installation.
Uses an enclosed body and sound-absorbing materials to reduce operating noise.
May include additional insulation, exhaust silencing, and airflow management. Exact noise claims require verified test data.
Supports movement between worksites. Confirm axle capacity, towing arrangement, brakes, lights, tyres, and local registration requirements.
Suitable for larger generator systems requiring enhanced weather protection, sound reduction, integrated controls, or larger fuel storage.
The supplier lists a noise level of approximately 70–75 dBA. This figure should only be published with:
Test distance
Generator load
Enclosure type
Measurement method
Ambient test conditions
Open-frame models will normally have different noise performance from silent or containerized models.
The PLD-3GF generator range may be suitable for:
Mines
Construction sites
Oil fields
Hospitals
Schools
Ports
Hotels
Warehouses
Manufacturing plants
Commercial buildings
Agricultural facilities
Telecommunications
Emergency response
Remote power projects
Hospital and life-safety systems require professional engineering, approved transfer equipment, redundancy planning, and local regulatory compliance.
A qualified generator technician and electrical contractor should complete installation and commissioning.
Typical requirements include:
Reinforced foundation
Electrical grounding
Exhaust routing
Ventilation
Fuel-system installation
Circuit protection
Transfer switch
Distribution connection
Fire-safety measures
Load testing
Controller programming
Never operate a diesel generator inside an occupied or inadequately ventilated space.
The listed warranty is 12 months or 1500 operating hours, whichever occurs first.
Before publishing, confirm:
Covered engine components
Alternator coverage
Controller coverage
Labour terms
Spare-parts support
Service location
Maintenance requirements
Warranty exclusions
The supplier lists CE and ISO certification. Only documents that apply to the exact generator model, engine, alternator, controller, and manufacturing facility should appear in the final listing.
Diesel generators produce carbon monoxide, hot exhaust gases, hazardous voltage, noise, vibration, and moving mechanical parts.
Use trained professionals for lifting, installation, grounding, fuel connections, electrical wiring, commissioning, operation, and maintenance. Never exceed the verified prime or standby power rating.