Welcome to Mega Source online store

Your cart is currently empty.

Trailer Mounted Mobile Ligh...

Illuminate construction sites, roadworks, mining areas, emergency zones, and remote outdoor workplaces with the YG Mobile LED Light Tower. Designed for temporary wide-area illumination, the system combines industrial LED floodlights, a telescopic mast, adjustable lamp heads, stabilizing support legs, and a mobile trailer-mounted chassis.

Available configurations may include diesel-generator, gasoline-generator, solar, battery, AC, and DC power systems. Manual mast lifting is available as the standard option, while hydraulic lifting may be selected for compatible models.

Because this is a customizable industrial product, each configuration should be listed separately with its exact lamp output, engine, generator, mast, runtime, fuel capacity, dimensions, weight, accessories, and price.

Key Features

  • High-output industrial LED floodlights

  • Telescopic mast extending up to approximately 9 m

  • Manual mast-lifting system

  • Optional hydraulic lifting configuration

  • Adjustable lamp-head direction

  • Mobile trailer-mounted chassis

  • Stabilizing support legs

  • Diesel, gasoline, solar, battery, AC, or DC configurations

  • Optional Kubota diesel engine

  • Wide-area outdoor illumination

  • Multiple colour-temperature options

  • High listed colour-rendering performance

  • IP66-rated components, subject to verification

  • Custom lamp, mast, power, and trailer configurations

  • One-year warranty

Product Specifications

  • Brand: YG or Customized Branding

  • Product Type: Mobile LED Lighting Tower

  • Application: Construction, Roadwork, Mining, Emergency Response, and Outdoor Work

  • Light Source: LED

  • Lamp Type: Industrial LED Floodlight

  • Number of Lamp Heads: Confirm for Selected Configuration

  • Power per Lamp: Confirm for Selected Configuration

  • Listed Luminous Output: 45,000 lm

  • Alternative Listed Output: 440,000 lm

  • Verified Total Output: Confirm Before Publishing

  • Listed Luminous Efficiency: Up to Approximately 165 lm/W

  • Colour Rendering Index: Listed as Ra 90

  • Colour-Temperature Options: 2700K, 3500K, 4100K, 5000K, or 6000K

  • Optional Emitting Colours: Red, Blue, Yellow, Green, Warm White, or Cool White

  • Overall Lighting Coverage: Approximately 360°, subject to lamp arrangement

  • Mast Type: Telescopic

  • Maximum Mast Height: Up to Approximately 9 m

  • Standard Lifting Method: Manual

  • Optional Lifting Method: Hydraulic

  • Engine Option: Kubota Diesel Engine

  • Generator Options: Diesel or Gasoline

  • Alternative Power Systems: Solar, Battery, AC, or DC

  • Applicable AC Input: Approximately 220V ±10%

  • Dimming: Not Supported on the Listed Standard Configuration

  • Lamp Housing Material: Steel

  • Protection Rating: IP66, subject to component-level confirmation

  • Listed LED Service Life: Up to Approximately 30,000 Hours

  • Operating Temperature: Confirm Full Ambient Range

  • Trailer Type: Confirm Before Publishing

  • Tow Connection: Confirm Before Publishing

  • Fuel-Tank Capacity: Confirm Before Publishing

  • Continuous Runtime: Confirm Before Publishing

  • Noise Level: Confirm Before Publishing

  • Overall Dimensions: Confirm Before Publishing

  • Machine Weight: Confirm Before Publishing

  • Customization: Available

  • Warranty: One Year

  • Country of Origin: Henan, China

High-Output LED Lighting

The mobile lighting tower uses industrial LED floodlights to illuminate large temporary work areas.

Potential advantages include:

  • High light output

  • Reduced electrical consumption

  • Fast startup

  • Lower maintenance requirements

  • Longer service life than many conventional lamps

  • Reduced heat generation

  • Flexible lamp positioning

  • Improved visibility across large outdoor sites

The exact lamp quantity, wattage, beam angle, and luminous output must be confirmed for each configuration.

Luminous-Output Conflict

Two different total output values are supplied:

  • 45,000 lumens

  • 440,000 lumens

These values may belong to different lamp packages or tower models.

Before publication, confirm:

  • Number of lamp heads

  • Wattage per lamp

  • Lumens per lamp

  • Complete-system output

  • Delivered luminaire output

  • Illuminated area

  • Lux level at specified distances

  • Photometric test conditions

Do not combine both output values in one purchasable variant.

LED Efficiency

The listed luminous efficiency is up to approximately 165 lm/W.

Confirm whether this figure applies to:

  • The bare LED chips

  • The LED modules

  • The complete floodlight

  • The complete lighting system after driver and optical losses

Actual efficiency depends on LED quality, driver performance, thermal management, optical design, and operating temperature.

Colour-Temperature Options

Available colour temperatures may include:

  • 2700K: Soft Warm White

  • 3500K: Warm White

  • 4100K: Neutral White

  • 5000K: Daylight White

  • 6000K: Cool Daylight

Neutral-white and daylight configurations are generally appropriate for construction, roadwork, maintenance, and industrial operations.

Each colour-temperature option should have its own verified lumen output and CRI specification.

Optional Coloured Lighting

Optional emitting colours may include:

  • Red

  • Blue

  • Yellow

  • Green

  • Warm White

  • Cool White

  • Changeable Colour

These options may be suitable for emergency identification, warning applications, events, or specialist projects.

Coloured lighting should not be presented as standard unless included in the selected configuration.

Wide-Area Coverage

The supplied beam-angle value of 365° is not a conventional optical specification.

It may refer to:

  • Approximately 360° total site coverage

  • Mast rotation

  • Multiple independently adjustable lamp heads

  • Combined horizontal illumination

The final technical data should provide:

  • Individual horizontal beam angle

  • Individual vertical beam angle

  • Mast rotation range

  • Lamp-head tilt range

  • Complete photometric distribution

Telescopic Mast

The tower may be equipped with a telescopic mast extending up to approximately 9 m.

An elevated mast can improve:

  • Light distribution

  • Coverage area

  • Shadow reduction

  • Visibility around machinery

  • Illumination of road and construction zones

Before publication, confirm:

  • Retracted mast height

  • Extended mast height

  • Number of sections

  • Mast material

  • Rotation range

  • Locking mechanism

  • Wind-speed rating

  • Raising time

  • Lowering time

  • Emergency lowering system

Manual Mast Lifting

The standard configuration uses a manual lifting system.

Confirm whether this uses:

  • Hand winch

  • Mechanical crank

  • Cable-and-pulley system

  • Self-locking brake

  • Mechanical safety pins

Operators should follow all leveling, lifting, inspection, and wind-safety requirements.

Optional Hydraulic Mast

Selected models may use hydraulic mast lifting.

Hydraulic and manual versions should be listed separately because they may differ in:

  • Price

  • Setup time

  • Machine weight

  • Maintenance

  • Control system

  • Power requirements

  • Emergency-lowering procedure

Kubota Diesel Engine Option

A Kubota diesel engine may be offered on selected configurations.

Before publication, confirm:

  • Exact engine model

  • Rated output

  • Number of cylinders

  • Cooling system

  • Displacement

  • Fuel consumption

  • Emissions certification

  • Starting system

  • Service interval

  • Spare-parts availability

Do not advertise every unit as Kubota-powered unless the selected product includes that engine.

Generator Options

Available configurations may include:

  • Diesel generator

  • Gasoline generator

  • External AC operation

  • DC operation

  • Battery-powered operation

  • Solar-assisted operation

  • Hybrid solar and battery operation

Each configuration should have separate:

  • Technical specifications

  • Product images

  • Runtime

  • Fuel or battery capacity

  • Dimensions

  • Weight

  • Price

  • Package contents

Solar Configuration

Before listing a solar-powered model, confirm:

  • Solar-panel wattage

  • Panel quantity

  • Battery chemistry

  • Battery capacity

  • Charge-controller type

  • Charging duration

  • Runtime per charge

  • Cloudy-weather autonomy

  • External backup charging

  • Battery cycle life

AC and DC Configurations

Selected versions may support AC 220V ±10%, DC input, or an external electrical supply.

Confirm:

  • Voltage range

  • Frequency

  • Electrical phase

  • Plug or connector type

  • Rated input current

  • Grounding requirements

  • Circuit protection

  • External cable specification

  • Generator bypass operation

Mobile Trailer Chassis

The trailer-mounted chassis supports transportation between work locations.

Before publication, confirm:

  • Overall trailer dimensions

  • Axle rating

  • Tyre size

  • Suspension

  • Tow-hitch type

  • Maximum towing speed

  • Parking brake

  • Safety chains

  • Road lights

  • Reflectors

  • Regional road-use certification

Do not describe the trailer as road legal without destination-market approval.

Stabilizing Support Legs

The tower may include adjustable support legs or outriggers.

Confirm:

  • Number of stabilizers

  • Manual or hydraulic adjustment

  • Maximum extension

  • Ground-pad size

  • Locking mechanism

  • Maximum ground slope

  • Level indicators

  • Safety interlocks

The mast should only be raised after the unit has been properly positioned and stabilized.

IP66 Protection

The listed IP66 rating may indicate dust-tight protection and resistance to strong water jets.

Confirm whether this applies to:

  • LED lamp heads

  • Electrical control enclosure

  • Generator enclosure

  • Battery compartment

  • Cable connectors

  • Complete lighting tower

Only tested components should carry the IP66 claim.

LED Service Life

The LED system has a listed service life of up to approximately 30,000 hours.

Actual service life depends on:

  • Ambient temperature

  • Driver quality

  • Heat dissipation

  • Vibration

  • Dust exposure

  • Power quality

  • Switching cycles

  • Maintenance

The lamp-life claim should not be presented as the warranty period.

Operating Temperature

A supplier value of 75°C is incomplete and may refer to:

  • Maximum ambient temperature

  • LED junction temperature

  • Fixture surface temperature

  • Incorrect product data

Confirm the complete minimum and maximum ambient operating-temperature range before publication.

Colour Rendering

The lighting system is listed with a colour-rendering index of Ra 90.

This may improve visibility of:

  • Surface details

  • Cable colours

  • Equipment markings

  • Safety signs

  • Work materials

Confirm whether Ra 90 applies to every colour-temperature and lamp configuration.

Suitable Applications

The mobile LED lighting tower may be suitable for:

  • Construction sites

  • Road building and maintenance

  • Mining and quarry operations

  • Emergency response

  • Disaster-relief work

  • Utility repairs

  • Night-time maintenance

  • Ports and warehouses

  • Oil and gas work sites

  • Outdoor industrial operations

  • Temporary event lighting

  • Remote job sites

The final configuration should be selected according to required output, runtime, mast height, environmental conditions, transportation, and available power.

Customization Options

Available custom options may include:

  • Lamp quantity

  • Lamp wattage

  • Total luminous output

  • Colour temperature

  • Coloured lighting

  • Mast height

  • Manual or hydraulic lifting

  • Diesel or gasoline engine

  • Generator brand

  • Solar-panel system

  • Battery capacity

  • Trailer size

  • Tow-hitch type

  • Electrical controls

  • Housing colour

  • Branding and packaging

Each customized unit should receive an approved technical specification and final quotation before production.

Safety Features to Confirm

Confirm whether the selected configuration includes:

  • Emergency stop

  • Circuit breakers

  • Overload protection

  • Low-oil shutdown

  • Engine overtemperature protection

  • Mast safety lock

  • Wind-speed warning

  • Electrical grounding

  • Trailer parking brake

  • Stabilizer interlock

  • Battery-management protection

Only installed and tested safety features should be advertised.

Package Contents

Depending on the selected configuration, the package may include:

  • Mobile lighting tower

  • LED floodlight heads

  • Telescopic mast

  • Diesel or gasoline generator

  • Solar or battery system

  • Trailer chassis

  • Stabilizing support legs

  • Electrical control panel

  • Charging equipment

  • Power cables

  • Tool kit

  • User manual

  • Maintenance documentation

Confirm packaging dimensions, gross weight, loading method, and assembly requirements separately.

Warranty

The listed warranty period is one year.

Before publication, confirm coverage for:

  • LED lamp heads

  • LED drivers

  • Engine

  • Generator

  • Mast

  • Manual or hydraulic lifting system

  • Solar panels

  • Battery

  • Trailer chassis

  • Electrical controls

  • Labour

  • Replacement parts

  • Return shipping

Warranty terms may differ between standard and customized components.

Important Safety Information

Place the lighting tower on firm, level ground and fully deploy the support legs before raising the mast.

Do not exceed the manufacturer’s approved wind-speed limit. Maintain safe clearance from overhead electrical cables, cranes, buildings, trees, and other obstructions.

Inspect the lamps, mast, lifting cables, generator, trailer, electrical system, and stabilizers before each use.

Operate diesel and gasoline engines only in properly ventilated outdoor areas. Follow all applicable towing, electrical, workplace, environmental, and equipment-safety regulations.

Translation missing: en.general.search.loading