- Total R 0.00
Provide reliable prime or standby electricity for commercial, industrial, construction, and emergency applications with the YG Silent Diesel Generator Set. The detailed configuration features a rated output of 30kW, a water-cooled diesel engine, and a sound-reducing enclosure designed to lower operating noise and protect major components.
The generator may be configured for single-phase or three-phase operation, 50Hz or 60Hz frequency, and multiple regional output voltages. Automatic and remote-start options may also be available depending on the selected controller and final build.
Because the supplied information includes several power, engine, voltage, model, and weight options, each configuration should be verified and listed separately.
30kW rated diesel generator configuration
Silent sound-reducing enclosure
Water-cooled diesel engine
Prime or standby power applications
Single-phase or three-phase options
50Hz or 60Hz configurations
Automatic-start capability
Remote-start option
Multiple voltage configurations
Extended fuel-tank operating time
Commercial and industrial applications
12-month or 500-hour limited warranty
Optional stationary, portable, or mobile configurations
Brand: YG, subject to confirmation
Detailed Model: YG-30KW
Alternative Listed Model: NP150W
Product Type: Silent Diesel Generator Set
Rated Power: 30kW
Equivalent Apparent Power: Confirm kVA rating according to power factor
Engine Type: Water-Cooled Diesel Engine
Engine Brand Options: Ricardo, Weichai, Cummins, or Isuzu
Cooling System: Water Cooling
Output Voltage: 220V / 400V for detailed model
Alternative Voltage Options: 110V, 220V, 230V, 240V, or 380V
Phase Options: Single Phase or Three Phase
Frequency Options: 50Hz or 60Hz
Engine Speed: 1500 RPM at 50Hz or 1800 RPM at 60Hz
Starting System: Electric, Automatic, or Remote Start
Listed Rated Current: 36A, subject to phase and voltage confirmation
Fuel-Tank Runtime: Approximately 8–10 Hours, subject to load
Enclosure Type: Silent or Sound-Reducing Canopy
Alternative Formats: Open Frame, Portable, or Mobile Type
Detailed Listed Weight: Approximately 880 kg
Alternative Listed Weight: 330 kg, subject to model confirmation
Listed Dimensions: 1330 × 750 × 1000 mm, subject to selected model
Warranty: 12 Months or 500 Operating Hours
Certifications: CE, ISO 9001, ISO 14001, and ISO 45001, subject to valid documentation
Country of Origin: Henan, China
The water-cooling system is designed to manage operating temperature during extended use. Compared with smaller air-cooled systems, water-cooled engines are commonly selected for larger commercial and industrial generator applications.
Available engine-brand options may include:
Ricardo
Weichai
Cummins
Isuzu
The final listing should identify the exact engine brand, model, displacement, cylinder count, fuel consumption, and rated mechanical output.
The generator may be supplied with a sound-reducing canopy designed to:
Reduce operating noise
Protect internal components
Improve outdoor durability
Limit contact with moving and hot parts
Provide easier access for servicing
Confirm the tested noise level in dB at a specified distance before advertising an exact silent-performance claim.
The detailed model is listed as a 30kW generator with 220V/400V output. Other voltage, phase, and frequency configurations may be available.
Each product variant should specify:
Rated power in kW
Rated apparent power in kVA
Standby power
Rated voltage
Rated current
Phase
Frequency
Power factor
Engine speed
Do not use the same current value across every voltage and phase option.
Depending on the selected control panel, the generator may support:
Manual electric starting
Automatic starting
Remote starting
Automatic mains-failure operation
Emergency stop
Status and fault monitoring
Confirm whether an ATS panel is included or sold separately.
The integrated fuel tank is stated to support approximately 8–10 hours of operation. Actual runtime depends on:
Electrical load
Fuel-tank capacity
Engine efficiency
Ambient temperature
Maintenance condition
Selected engine model
Fuel consumption at 25%, 50%, 75%, and 100% load should be confirmed before publishing.
The YG silent diesel generator may be suitable for:
Commercial buildings
Hotels
Telecommunications
Construction sites
Warehouses
Manufacturing facilities
Mining operations
Shopping centres
Entertainment venues
Agricultural facilities
Emergency backup systems
Remote work sites
Hospital or life-safety applications require a properly engineered installation, compliant transfer equipment, and local regulatory approval.
A qualified generator technician or electrical contractor should complete the installation. The setup may require:
Concrete foundation
Earthing and grounding
Exhaust routing
Fuel-system installation
Ventilation
Circuit protection
Transfer switch
Distribution panel
Weather protection
Load testing
The generator should not be operated in enclosed or poorly ventilated spaces due to carbon-monoxide risk.
Regular maintenance may include:
Engine-oil replacement
Fuel-filter replacement
Air-filter inspection
Coolant checks
Battery testing
Belt inspection
Fuel-system inspection
Electrical connection checks
Load-bank testing
Follow the maintenance schedule supplied with the exact engine and alternator model.
The listed warranty is 12 months or 500 operating hours, whichever occurs first. Confirm:
Covered components
Labour coverage
Spare-parts policy
Warranty start date
Service location
Exclusions
Required maintenance records
Diesel generators produce dangerous exhaust gases, including carbon monoxide. Operate the generator only in a properly ventilated outdoor or engineered generator-room environment.
Use qualified personnel for installation, grounding, fuel connections, electrical wiring, commissioning, and maintenance. Do not exceed the verified rated or standby output.