- Total R 0.00
Provide dependable primary or backup electricity with the VG Silent Diesel Generator Set. Available in approximately 20 kW to 30 kW configurations, this industrial generator is designed for commercial buildings, construction sites, farms, workshops, factories, remote facilities, and emergency power systems.
The water-cooled diesel engine supports extended operation under demanding conditions, while the sound-reducing enclosure helps lower operating noise compared with an open-frame generator. A brushless, self-excited alternator and automatic voltage regulator help maintain consistent electrical output for compatible machinery, appliances, and electrical systems.
The LCD digital control panel provides convenient access to essential operating data. Multiple voltage, frequency, phase, fuel-tank, alternator, and enclosure configurations are available depending on the selected model.
Silent enclosed diesel generator
Power options between approximately 20 kW and 30 kW
Water-cooled diesel engine
Electric starting system
LCD digital control panel
Automatic voltage regulation
Brushless, self-excited alternator
Single-phase and three-phase options
50 Hz and 60 Hz configurations
Multiple international voltage options
Extended-runtime fuel tank options
IP23 enclosure rating
Open, silent, trailer, and containerized formats available
Suitable for primary and emergency backup power
CE-certified configuration
Custom specifications available
Brand: VG
Engine Brand: SANNEY POWER, subject to confirmation
Model: VG-R28
Product Type: Silent Diesel Generator Set
Rated Power: Confirm Selected 20–30 kW Configuration
Rated Apparent Power: Confirm Selected kVA Rating
Fuel Type: Diesel
Output Voltage Options: 110 V, 220 V, 230 V, 240 V, 380 V, 400 V, 415 V, or 480 V
Standard Output Options: 220 V or 400 V
Frequency: 50 Hz or 60 Hz
Phase Options: Single Phase or Three Phase
Engine Speed: 1500 RPM or 1800 RPM
Starting System: 12 V or 24 V DC Electric Start
Starting Battery: Included
Cooling System: Water Cooling
Control Panel: LCD Digital Display
Alternator Type: Self-Excited Brushless Alternator
Voltage Regulation: Automatic Voltage Regulator
Steady-State Voltage Regulation: Less Than ±1.5%
Enclosure Rating: IP23
Working Temperature: Approximately -40°C to 55°C
Weight: Approximately 890 kg, subject to configuration
Packaging: Plywood Case and Protective Plastic Film
Warranty: Confirm as 1–2 Years or 2 Years/2000 Hours
Country of Origin: Fujian, China
Depending on the selected configuration, the generator may be supplied with:
China Stamford-type alternator
Original Stamford alternator
Marathon alternator
Leroy-Somer alternator
Mecc Alte alternator
The final listing should identify only the alternator installed in the purchased generator.
Available formats may include:
Open-frame generator
Silent canopy generator
Mobile trailer generator
Containerized generator
Dimensions, weight, noise output, shipping cost, and installation requirements vary according to the selected format.
Extended-runtime fuel-tank configurations may support approximately:
8–10 hours
12 hours
24 hours
48 hours
Actual runtime varies according to generator load, fuel-tank capacity, engine condition, ambient temperature, and operating environment.
The digital control panel may display information such as:
Output voltage
Electrical frequency
Current
Generator load
Engine speed
Operating time
Battery status
Warning and fault information
Exact display functions depend on the selected controller.
The generator’s AVR system helps maintain consistent output voltage when the electrical load changes. Additional protection systems may be available depending on the chosen controller and configuration.
Confirm whether the selected model includes:
Overload protection
Low-oil pressure shutdown
High-temperature shutdown
Over-voltage protection
Under-voltage protection
Short-circuit protection
Emergency stop
Automatic mains-failure controls
This diesel generator is suitable for:
Commercial buildings
Construction sites
Farms and agricultural facilities
Workshops
Factories and manufacturing plants
Warehouses
Remote offices and facilities
Telecommunications equipment
Emergency power installations
Off-grid power systems
Compatible industrial machinery
Select the generator according to:
Total running load
Motor and equipment starting load
Required output voltage
Single-phase or three-phase requirement
Required frequency
Daily operating duration
Environmental temperature
Noise restrictions
Required standby or continuous rating
Installation and connection should be completed by qualified generator and electrical professionals.
Operate the generator outdoors or in a professionally designed and ventilated generator room. Diesel exhaust contains carbon monoxide and other hazardous gases.
Do not operate the generator inside homes, garages, basements, enclosed workshops, or poorly ventilated spaces. Follow all manufacturer instructions for grounding, exhaust routing, cooling, fuel storage, electrical connection, operation, and maintenance.