- Total R 0.00
Provide portable wide-area illumination for construction sites, road maintenance, mining operations, emergency response, outdoor events, industrial work, and remote locations with this Custom Mobile LED Lighting Tower.
The system can be configured with two, four, six, or eight LED lamps, individual lighting power from approximately 50W to 400W, generator capacities from 700W to 5000W, and battery banks ranging from approximately 100Ah to 1000Ah.
Available battery technologies include Gel, LiFePO4, AGM, and conventional lead-acid batteries. Mast options include manual, hand-cranked, electric, pneumatic, and hydraulic lifting systems, with carbon-steel or 304 stainless-steel construction.
Because this is a configurable industrial product, the final lamp quantity, total lighting power, battery chemistry, battery capacity, generator size, mast height, input voltage, output voltage, runtime, dimensions, weight, and package contents must be confirmed for each selected configuration.
Custom mobile lighting-tower configuration
Two, four, six, or eight lamp options
Individual lamp power from approximately 50W to 400W
Generator power options from approximately 700W to 5000W
Battery capacities from approximately 100Ah to 1000Ah
Gel, LiFePO4, AGM, or lead-acid battery options
AC and multiple DC voltage configurations
Manual, electric, pneumatic, or hydraulic mast options
Carbon-steel or 304 stainless-steel mast construction
5000K daylight illumination
Listed IP66 environmental protection
Metal lighting and structural components
Lighting and electrical-circuit design service
Custom output-voltage options
One-year warranty
Brand: Confirm Before Publishing
Product Name: Mobile Lighting Tower
Product Type: Custom Generator and Battery-Powered Lighting Tower
Primary Application: Temporary Outdoor and Industrial Lighting
Fixture Type: Customizable
Light Source: Confirm as LED Before Publishing
Lamp Quantity Options: Two, Four, Six, or Eight
Individual Lamp Power: Approximately 50W–400W
Total Lighting Power: Configuration Dependent
Listed Lighting Output: 40,000, exact unit and configuration to be confirmed
Colour Temperature: Approximately 5000K Daylight
Lamp and Housing Material: Metal
Battery Options: Gel, LiFePO4, AGM, or Lead-Acid
Battery Capacity Range: Approximately 100Ah–1000Ah
Battery Voltage: Confirm for Selected Configuration
Input Voltage Options: AC220V, DC24V, DC48V, or DC72V
Primary Listed Input: DC24V
Output Voltage Options: DC12V, DC24V, DC36V, DC48V, DC72V, or AC220V
Generator Power Options: 700W, 1000W, 2000W, 3000W, or 5000W
Power Source: Generator and Battery
Charging System: Confirm Before Publishing
Mast Types: Manual, Hand-Cranked, Electric, Pneumatic, or Hydraulic
Mast Material: Carbon Steel or 304 Stainless Steel
Mast Height: Confirm Before Publishing
Mast Rotation: Confirm Before Publishing
Lamp-Head Adjustment: Confirm Before Publishing
Protection Rating: IP66, subject to component verification
Mobility System: Confirm Before Publishing
Stabilizing Supports: Confirm Before Publishing
Assembly Required: Yes
Operating Temperature: Confirm Before Publishing
Continuous Runtime: Confirm Before Publishing
Charging Time: Confirm Before Publishing
Overall Dimensions: Confirm Before Publishing
Total Weight: Confirm Before Publishing
Customization: Supported
Warranty: One Year
Country of Origin: Henan, China
This mobile lighting tower is not a single fixed model.
It can be configured according to:
Required illuminated area
Number of lamp heads
Wattage per lamp
Required runtime
Available charging source
Battery technology
Generator output
Mast height
Mobility requirements
Site environmental conditions
Each completed configuration should receive its own technical data sheet, SKU, product images, price, and package information.
Available lamp configurations include:
Two lamps
Four lamps
Six lamps
Eight lamps
The selected quantity affects:
Total luminous output
Electrical load
Generator size
Battery runtime
Mast load
Weight
Wind resistance
Overall cost
The final product page should show one exact lamp quantity per purchasable variant.
Each lamp may be configured between approximately 50W and 400W.
Possible total loads include:
Two 50W lamps: 100W total
Four 100W lamps: 400W total
Six 200W lamps: 1200W total
Eight 400W lamps: 3200W total
These are examples only. The actual total load must include:
LED drivers
Mast motor
Charging system
Control equipment
Auxiliary outputs
System losses
The generator and battery should be sized above the complete continuous load.
The supplied field states “Lamp Luminous Efficiency: 40000.”
This is not a valid efficiency value because luminous efficiency should be expressed in lumens per watt.
The 40,000 figure may represent:
Total luminous output
Output from one lamp configuration
A rounded marketing value
Incorrect supplier data
Before publication, confirm:
Total lumens
Lumens per watt
Lamp wattage
Lamp quantity
Output after optical losses
Maintained lumen level
The standard listed colour temperature is approximately 5000K.
This produces a daylight-style white appearance that may support:
Construction work
Road maintenance
Equipment operation
Security areas
Warehouses
Outdoor emergency work
Industrial maintenance
Confirm the colour-rendering index and whether alternative colour temperatures are available.
The system may use several battery technologies.
LiFePO4 batteries may offer:
High cycle life
Lower weight than many lead-acid systems
Stable voltage
Integrated battery-management compatibility
Improved usable capacity
Confirm:
Cell manufacturer
Battery-management system
Cycle-life rating
Maximum discharge current
Charging temperature
Warranty period
Gel batteries may offer:
Sealed construction
Reduced electrolyte leakage risk
Deep-cycle operation
Lower maintenance requirements
Confirm recommended discharge depth and charging profile.
AGM batteries may provide:
Sealed maintenance-free construction
High current delivery
Familiar charging requirements
Good vibration resistance
Confirm cycle life and usable capacity.
Conventional lead-acid batteries may provide a lower initial cost but are generally heavier and may require more maintenance.
Battery types should not be combined within the same battery bank unless expressly approved by the manufacturer.
Available capacity is listed from approximately 100Ah to 1000Ah.
Battery capacity alone does not define stored energy.
The final specification must also include voltage.
For example:
24V × 100Ah = 2.4kWh nominal energy
48V × 500Ah = 24kWh nominal energy
72V × 1000Ah = 72kWh nominal energy
Actual usable energy depends on battery chemistry, permitted discharge depth, system efficiency, temperature, and battery condition.
Runtime must be calculated using:
Battery voltage
Battery capacity
Total lamp power
Driver efficiency
Inverter losses
Mast and control consumption
Permitted depth of discharge
A verified runtime test should be provided for each configuration.
Do not advertise a universal runtime across 100Ah and 1000Ah battery systems.
Available generator capacities include:
700W
1000W
2000W
3000W
5000W
Before publication, confirm whether these are:
Continuous output ratings
Maximum output ratings
Charging-generator ratings
Combined AC output ratings
A 700W generator will not support a high-power multi-lamp configuration if the total continuous load exceeds its rated capacity.
The lighting tower may combine a generator with battery storage.
Possible operating modes may include:
Generator directly powers lamps
Generator charges batteries
Batteries power lamps quietly
Automatic generator start at low battery
Generator and battery operate together
External AC charging
Before publication, confirm:
Automatic transfer function
Generator-start logic
Charging power
Battery-management system
Inverter rating
Low-voltage protection
Emergency shutdown
Manual override
The product lists multiple input voltages:
AC220V
DC24V
DC48V
DC72V
These should be treated as separate electrical configurations.
The final listing should state:
Exact input voltage
Voltage tolerance
Frequency for AC input
Maximum input current
Connector type
Required circuit protection
Charging method
Available output voltages include:
DC12V
DC24V
DC36V
DC48V
DC72V
AC220V
Before publication, confirm:
Output socket quantity
Maximum current per output
Continuous output capacity
Surge capacity
Inverter type
Pure sine wave or modified sine wave
Overload protection
Grounding arrangement
Do not list all outputs as standard unless the selected control system includes them.
A manual mast may use direct mechanical lifting or sectional extension.
Potential benefits include:
Simple construction
Lower maintenance
Reduced power consumption
Easier repair
Confirm:
Maximum height
Number of sections
Locking pins
Raising procedure
Maximum load
Wind-speed limitation
A hand-cranked mast may use a mechanical winch.
Before publication, confirm:
Winch load rating
Cable material
Safety brake
Mechanical lock
Inspection interval
Emergency lowering method
An electric mast may use an electric winch or actuator.
Confirm:
Operating voltage
Motor power
Raising time
Lowering time
Limit switches
Manual emergency operation
Overload protection
A pneumatic mast may use compressed air for extension.
Confirm:
Required pressure
Integrated compressor
Extension time
Maximum height
Locking system
Air-leak protection
Maintenance requirements
A hydraulic mast may offer powered lifting for heavier lamp assemblies.
Confirm:
Hydraulic-pump type
Operating pressure
Oil specification
Safety valve
Manual emergency release
Extension time
Maintenance interval
The mast may be manufactured from:
Carbon steel
304 stainless steel
Carbon steel may provide:
High structural strength
Lower cost
Easy fabrication
Powder-coating options
Its corrosion resistance depends on surface treatment.
304 stainless steel may provide:
Improved corrosion resistance
Better appearance
Reduced coating requirements
Suitability for demanding environments
It may increase product weight and cost.
The listed IP66 rating may provide:
Dust-tight enclosure protection
Resistance to strong water jets under defined test conditions
Before publication, confirm whether IP66 applies to:
Lamp heads
Battery cabinet
Electrical control enclosure
Generator controls
Connectors
Complete machine
IP66 does not mean the lighting tower is designed for underwater use.
The product is listed as requiring assembly.
Before publication, explain whether assembly includes:
Installing lamp heads
Connecting cables
Attaching mast sections
Mounting wheels
Installing outriggers
Connecting battery terminals
Filling generator fluids
Commissioning the control panel
Heavy or electrical assembly should be completed by qualified personnel.
The listing does not identify whether the unit uses:
Hand-push wheels
Trailer chassis
Skid base
Forklift pockets
Lifting points
Self-loading system
Confirm:
Total weight
Wheel and axle specification
Towing requirements
Stabilizer quantity
Maximum permitted slope
Wind-speed restrictions
Lighting and circuitry design may help determine:
Lamp quantity
Lamp wattage
Mast height
Required lux level
Battery size
Generator capacity
Cable sizing
Control-panel design
Runtime
Charging requirements
A final electrical load calculation should be completed before production.
The mobile lighting tower may be suitable for:
Construction sites
Road repairs
Mining and quarry operations
Emergency response
Disaster-relief work
Outdoor events
Ports and warehouses
Utility maintenance
Railway work
Industrial shutdowns
Remote job sites
Temporary security lighting
The final configuration should match the required output, runtime, environmental conditions, and transport method.
Available customization may include:
Lamp quantity
Lamp power
Total luminous output
Battery chemistry
Battery voltage
Battery capacity
Generator size
Input voltage
Output voltage
Mast type
Mast height
Mast material
Wheel or trailer configuration
Control system
Automatic generator start
Remote monitoring
Housing colour
Branding
Each customized tower should receive an approved engineering drawing and technical specification before production.
Depending on the selected configuration, the package may include:
Mobile lighting-tower frame
Two, four, six, or eight lamp heads
Telescopic mast
Generator
Battery bank
Battery-management system
Charger
Inverter
Electrical control cabinet
Power and output sockets
Wheels, trailer, or skid base
Stabilizing outriggers
Power cables
Assembly hardware
User manual
Wiring diagram
Only verified included items should appear in the final listing.
The product includes a listed one-year warranty.
Before publication, confirm coverage for:
LED lamp heads
Drivers
Battery bank
Battery-management system
Generator
Inverter
Charger
Mast
Lifting system
Control cabinet
Wheels or trailer
Labour
Replacement parts
Return shipping
Battery, generator, and electrical components may have separate warranty periods.
Install and assemble the lighting tower according to the approved engineering drawings and wiring diagram.
Deploy all stabilizers on firm, level ground before extending the mast. Never move or transport the tower while the mast is raised.
Use qualified personnel for battery installation, high-voltage wiring, generator service, inverter connection, mast repairs, and system commissioning.
Observe correct battery polarity and use only the approved charger for the selected battery chemistry. Never mix different battery technologies, capacities, ages, or voltage ratings in the same battery bank.
Operate generator-equipped models only in properly ventilated outdoor areas because exhaust gases contain carbon monoxide.