Provide dependable standby or continuous electricity for industrial, commercial, construction, and remote-site applications with this 300kW Diesel Generator Set. The reference configuration combines a water-cooled diesel engine, copper-wound alternator, intelligent control panel, and a choice of open-frame or sound-reducing canopy construction.

The generator can be customized with different power ratings, voltage and frequency configurations, automatic transfer controls, larger fuel tanks, and mobile trailer systems. Each configuration should be quoted and listed separately with its exact engine, alternator, dimensions, weight, and electrical output.

Key Features

  • 300kW reference diesel generator configuration

  • Available power range from 10kW to 1000kW

  • Open-frame or silent-canopy options

  • Water-cooled diesel engine

  • Copper-wound alternator

  • Three-phase 230V/400V output configuration

  • Automatic start and stop support

  • Optional ATS automatic transfer system

  • Intelligent monitoring controller

  • Overload and overtemperature protection

  • Low-oil-pressure shutdown protection

  • Optional mobile trailer

  • Custom fuel-tank capacity

  • Industrial and commercial power applications

  • Custom voltage and frequency options

Product Specifications

  • Brand: Confirm Before Publishing

  • Manufacturer: Henan Yugong Machinery Co., Ltd., subject to verification

  • Product Type: Industrial Diesel Generator Set

  • Reference Rated Power: 300kW

  • Available Power Range: 10–1000kW

  • Standby Power: Confirm Before Publishing

  • Engine Type: Water-Cooled Diesel Engine

  • Engine Brand and Model: Confirm Before Publishing

  • Alternator Type: Copper-Wound Alternator

  • Rated Output Voltage: 230V / 400V

  • Phase: Three Phase

  • Frequency: Confirm as 50Hz or 60Hz

  • Rated Current: Confirm According to Voltage and Power Factor

  • Power Factor: Confirm Before Publishing

  • Structure Options: Open Frame or Silent Canopy

  • Starting System: Electric Start

  • Automatic Start: Available

  • Remote Monitoring: Available, subject to controller selection

  • ATS Compatibility: Available or Optional

  • Cooling System: Closed-Circuit Water Cooling

  • Reference Dimensions: 2900 × 1100 × 1800 mm

  • Reference Unit Weight: Approximately 2000 kg

  • Voltage Fluctuation Rate: Listed as ≤ ±0.49%, subject to verification

  • Starter Battery Included: Confirm Before Publishing

  • Fuel-Tank Capacity: Confirm Before Publishing

  • Runtime: Confirm According to Tank and Load

  • Noise Level: Confirm in dB at a Stated Distance

  • Warranty: Confirm Before Publishing

  • Country of Origin: China

Available Power Ratings

Possible generator configurations include:

  • 10kW

  • 30kW

  • 50kW

  • 100kW

  • 150kW

  • 200kW

  • 300kW

  • Higher-capacity models up to 1000kW

Every power rating should have its own product page or clearly defined variant with accurate specifications and pricing.

Water-Cooled Diesel Engine

The closed-circuit water-cooling system helps control engine temperature during extended operation. This configuration is suitable for larger commercial and industrial generator systems that may operate for long periods.

Before publishing, confirm:

  • Engine manufacturer

  • Engine model

  • Cylinder configuration

  • Displacement

  • Aspiration type

  • Rated speed

  • Fuel consumption

  • Lubricating-oil capacity

  • Coolant capacity

  • Applicable emissions standard

Copper-Wound Alternator

The alternator is described as using copper windings for reliable electrical output and heat resistance.

Confirm the following before publishing:

  • Alternator brand

  • Alternator model

  • Insulation class

  • Protection rating

  • Excitation system

  • Automatic voltage regulator

  • Voltage regulation accuracy

  • Alternator efficiency

Do not use “100% pure copper” unless verified by the manufacturer’s technical documentation.

Silent Canopy Option

The optional enclosed canopy is designed to reduce noise and protect internal equipment. It may include:

  • Sound-absorbing lining

  • Ventilation channels

  • Lockable service doors

  • Weather-resistant outer panels

  • Exhaust silencing system

  • Lifting points

  • Emergency-stop access

An exact low-noise claim should include a verified dB measurement and testing distance.

Open-Frame Option

The open-frame configuration provides easier access for servicing and installation inside a dedicated generator room.

It requires suitable:

  • Ventilation

  • Exhaust routing

  • Weather protection

  • Noise management

  • Fire protection

  • Access control

Intelligent Control Panel

Depending on the selected controller, the display may monitor:

  • Output voltage

  • Current

  • Frequency

  • Engine speed

  • Oil pressure

  • Coolant temperature

  • Battery voltage

  • Operating hours

  • Generator alarms

  • Shutdown conditions

Remote monitoring and automatic operation should only be advertised when included in the selected controller.

Protection Functions

The generator may include protection against:

  • Electrical overload

  • Short circuit

  • High coolant temperature

  • Low oil pressure

  • Overspeed

  • Underspeed

  • Overvoltage

  • Undervoltage

  • Emergency-stop activation

The exact protection system depends on the controller, breaker, and engine configuration.

ATS Automatic Transfer Option

An automatic transfer switch can start the generator and transfer the electrical load when the mains supply fails.

Confirm whether the ATS system is:

  • Included in the price

  • Supplied separately

  • Installed inside the generator enclosure

  • Provided as an external cabinet

  • Rated for the generator’s full output current

Suitable Applications

This industrial generator may be suitable for:

  • Construction sites

  • Manufacturing facilities

  • Warehouses

  • Commercial buildings

  • Hotels

  • Shopping centres

  • Schools

  • Agricultural facilities

  • Mining operations

  • Emergency response

  • Remote work sites

  • Telecommunications

  • Data and network equipment

  • Standby building power

Hospital and life-safety installations require professional engineering, approved transfer equipment, and compliance with local regulations.

Customization Options

Available customization may include:

  • Power rating

  • Engine brand

  • Alternator brand

  • Output voltage

  • Frequency

  • Single-phase or three-phase output

  • Silent canopy

  • Open frame

  • Automatic transfer switch

  • Remote monitoring

  • Mobile trailer

  • Fuel-tank capacity

  • Control-panel model

  • Socket and connection arrangement

  • Paint colour and branding

Installation Requirements

Installation should be completed by qualified generator and electrical professionals. Typical requirements include:

  • Reinforced foundation

  • Electrical grounding

  • Exhaust-gas routing

  • Ventilation

  • Fuel connections

  • Circuit protection

  • Load distribution

  • Automatic transfer equipment

  • Fire-safety measures

  • Commissioning and load testing

Never operate a diesel generator inside an occupied or poorly ventilated space because exhaust gases contain deadly carbon monoxide.

Maintenance Requirements

Routine maintenance may include:

  • Engine-oil replacement

  • Oil-filter replacement

  • Fuel-filter replacement

  • Air-filter inspection

  • Coolant checks

  • Starter-battery testing

  • Belt inspection

  • Fuel-system inspection

  • Alternator checks

  • Electrical-terminal tightening

  • Controller alarm testing

  • Load-bank testing

Maintenance intervals should follow the manual supplied with the exact engine and alternator.

Certifications

The supplier mentions:

  • CE

  • ISO 9001

  • ISO 14001

  • ISO 45001

Only certifications supported by valid documents covering the selected generator model and manufacturing facility should appear in the final listing.

Important Safety Information

Diesel generators produce carbon monoxide, hot exhaust gases, high voltage, noise, and moving mechanical parts.

Use trained professionals for delivery, lifting, installation, fuel connections, grounding, commissioning, operation, and maintenance. Do not exceed the verified prime or standby output.

Translation missing: en.general.search.loading