Welcome to Mega Source online store

Your cart is currently empty.

Customized Mobile Light Tow...

Provide reliable temporary illumination for construction sites, road maintenance, mining operations, emergency response, industrial work, outdoor events, and remote locations with the ANJ6150 Mobile Lighting Tower.

The lighting tower is available with metal-halide or LED lamp configurations, gasoline or diesel generator options, and manual or hydraulic mast lifting. Depending on the selected version, it may include two 1,000W lamps, four 400W lamps, four 300W LED lights, or four 200W LED lights.

Each machine configuration should be listed separately with its exact lamp technology, luminous output, generator capacity, fuel tank, runtime, mast height, dimensions, weight, and price.

Key Features

  • Mobile work-site lighting system

  • Metal-halide or LED lamp configurations

  • Up to 6 m standard mast height

  • Optional 7 m hydraulic mast version

  • Hand-cranked or hydraulic lifting

  • Gasoline or diesel generator options

  • 3 kW or 5 kW generator configurations

  • Adjustable individual lamp switching

  • Four stabilizing outriggers

  • 12-inch pneumatic tyres

  • Push-handle steering

  • Integrated wheel brake

  • Level 8 listed wind resistance

  • AC 220V electrical output

  • 50 Hz or 60 Hz configurations

  • IP65-rated components, subject to verification

  • One-year warranty

Product Specifications

  • Brand: ANJ

  • Model: ANJ6150

  • Product Type: Mobile Lighting Tower

  • Primary Light Source: Metal-Halide Lamp

  • Alternative Light Source: LED

  • Bulb Base: E40 on Applicable Metal-Halide Models

  • Input Voltage: AC 220V ±10%

  • Rated Generator Voltage: AC 220V

  • Frequency: 50 Hz or 60 Hz

  • Colour Temperature: Approximately 5000K–6000K for LED Versions

  • Metal-Halide Colour Temperature: Approximately 5400K

  • Colour Rendering Index: Ra 80

  • Listed Efficiency: Approximately 110 lm/W, subject to configuration

  • Listed Luminous Output: 330,000 lm, subject to verification

  • Verified Output Range in Comparison Table: Approximately 96,000–220,000 lm

  • Beam Angle: Approximately 60°

  • Protection Rating: IP65

  • Mast Material: Q235 Steel

  • Standard Mast Height: Approximately 6 m

  • Optional Mast Height: Approximately 7 m

  • Standard Lifting Method: Hand-Cranked

  • Optional Lifting Method: Hydraulic

  • Generator Power Options: 3 kW or 5 kW

  • Fuel Options: Gasoline or Diesel

  • Fuel-Tank Options: Approximately 12 L, 15 L, 16 L, or 25 L

  • Listed Runtime: Approximately 8–13 Hours

  • Engine Type: Single-Cylinder, Four-Stroke, Air-Cooled

  • Starting Options: Recoil Start or Electric Start

  • Generator Enclosure: Open-Frame or Silent Type

  • Wind Resistance: Listed as Level 8

  • Stabilizers: Four

  • Tyres: 12-Inch Pneumatic Tyres

  • Brake: Included

  • Lamp Controls: Main Switch and Individual Lamp Switches

  • Steering: Push-Handle Control

  • Machine Weight: Approximately 245–300 kg

  • Overall Dimensions: Approximately 1200 × 950 × 2100–2200 mm

  • Working Life: Up to Approximately 10,000 Hours for Listed Metal-Halide Lamps

  • Warranty: One Year

  • Country of Origin: Shanghai, China

Configuration Options

The supplied comparison table includes five different lighting-tower configurations.

Configuration 1: LED Open-Frame Tower

  • Four 200W or four 400W LED lamps

  • Approximately 96,000 or 192,000 lm

  • 6 m hand-cranked mast

  • 3 kW or 5 kW generator

  • Gasoline or diesel engine

  • Recoil start

  • Open-frame structure

  • Approximately 245 kg

  • Approximate dimensions: 1200 × 950 × 2100 mm

Configuration 2: Metal-Halide Open-Frame Tower

  • Two 1,000W or four 400W metal-halide lamps

  • Approximately 220,000 or 176,000 lm

  • 6 m hand-cranked mast

  • 3 kW or 5 kW generator

  • Diesel engine

  • Electric start

  • Open-frame structure

  • Approximately 265 kg

  • Approximate dimensions: 1200 × 950 × 2100 mm

Configuration 3: Single Metal-Halide Tower

  • One 1,000W metal-halide lamp

  • Approximately 110,000 lm

  • 6 m hand-cranked mast

  • 3 kW or 5 kW diesel generator

  • Electric start

  • Open-frame structure

  • Approximately 279 kg

  • Approximate dimensions: 1200 × 950 × 2200 mm

Configuration 4: Silent LED Tower

  • Four 300W LED lamps

  • Approximately 144,000 lm

  • 6 m hand-cranked mast

  • 5 kW silent diesel generator

  • 16 L fuel tank

  • Electric start

  • Approximately 280 kg

  • Approximate dimensions: 1200 × 950 × 2200 mm

Configuration 5: Hydraulic Silent LED Tower

  • Four 200W LED lamps

  • Approximately 96,000 lm

  • 7 m hydraulic mast

  • 5 kW silent diesel generator

  • 16 L fuel tank

  • Electric start

  • Approximately 300 kg

  • Approximate dimensions: 1200 × 950 × 2100 mm

These configurations should not share one price or one technical specification table.

Luminous-Output Conflict

The top specification lists approximately 330,000 lumens.

The detailed comparison table lists outputs including:

  • 96,000 lm

  • 110,000 lm

  • 144,000 lm

  • 176,000 lm

  • 192,000 lm

  • 220,000 lm

The 330,000-lumen value may belong to:

  • A different lamp package

  • A custom high-output model

  • A combined theoretical value

  • Incorrect marketplace data

Before publication, verify:

  • Number of lamps

  • Wattage per lamp

  • Lamp technology

  • Actual output per lamp

  • Complete system output

  • Photometric test report

Metal-Halide Lighting

Selected ANJ6150 configurations use metal-halide lamps.

Potential characteristics include:

  • High-intensity white light

  • Broad work-site illumination

  • Approximately 5400K colour temperature

  • E40 lamp-base compatibility

  • Warm-up period before full brightness

  • Restart delay after hot shutdown

  • Ballast requirement

  • Listed service life around 10,000 hours

Before publication, confirm:

  • Lamp manufacturer

  • Lamp wattage

  • Ballast type

  • Startup duration

  • Hot-restart time

  • Replacement-lamp availability

  • Lumen maintenance

LED Lighting Options

The comparison table also includes LED models with:

  • Four 200W lamps

  • Four 300W lamps

  • Four 400W lamps

LED versions may provide:

  • Instant startup

  • Lower maintenance

  • Reduced power consumption

  • Longer potential service life

  • Easier individual lamp control

  • Reduced restart delay

LED and metal-halide models should use separate titles and descriptions.

60-Degree Beam Angle

The listed beam angle is approximately 60 degrees.

Before publication, confirm whether this applies to:

  • Each individual lamp

  • Metal-halide reflector

  • LED floodlight optics

  • One specific model only

The complete site coverage also depends on mast height, lamp direction, lamp quantity, and spacing.

Hand-Cranked Mast

Most listed configurations use a hand-cranked lifting system.

Before publication, confirm:

  • Winch load rating

  • Cable material

  • Mast-section quantity

  • Safety brake

  • Mechanical locking pins

  • Raising time

  • Lowering time

  • Inspection interval

  • Emergency lowering method

Hydraulic Mast Option

The 7 m version uses hydraulic lifting.

Confirm:

  • Hydraulic pump type

  • Operating voltage

  • Maximum pressure

  • Raising time

  • Lowering time

  • Emergency manual release

  • Oil specification

  • Maintenance interval

  • Safety valve

Q235 Steel Mast

The mast is listed as Q235 steel.

Before publication, confirm:

  • Surface treatment

  • Paint or powder-coating thickness

  • Galvanization options

  • Corrosion resistance

  • Mast-wall thickness

  • Maximum lamp-head load

  • Wind-load testing

Generator Options

Generator capacities include approximately:

  • 3 kW

  • 5 kW

Before publication, confirm whether these represent:

  • Continuous rated output

  • Maximum output

  • Lighting-only output

  • Total auxiliary output

The generator must be sized for:

  • Lamp load

  • Ballast starting current

  • Mast controls

  • Battery charging

  • Auxiliary sockets

  • Electrical losses

Fuel Options

The product range includes gasoline and diesel engines.

Gasoline Version

Potential advantages may include:

  • Lower initial cost

  • Easier cold starting

  • Lower machine weight

Diesel Version

Potential advantages may include:

  • Longer continuous operation

  • Better fuel economy under industrial loads

  • Greater durability for frequent use

Each engine type should have separate emissions, runtime, maintenance, and fuel-consumption data.

Fuel-Tank Capacities

Listed fuel-tank options include:

  • 12 L

  • 15 L

  • 16 L

  • 25 L

The selected capacity depends on engine and generator configuration.

Before publication, confirm:

  • Fuel consumption at full load

  • Fuel consumption at typical lighting load

  • Continuous runtime

  • Fuel gauge

  • Low-fuel warning

  • Tank material

  • Refuelling access

Continuous Runtime

Runtime values include:

  • Approximately 8–13 hours

  • Approximately 10 hours

Actual runtime depends on:

  • Tank capacity

  • Engine type

  • Generator load

  • Lamp configuration

  • Fuel quality

  • Maintenance condition

  • Ambient temperature

The final listing should provide one verified runtime per machine configuration.

Open-Frame and Silent Versions

The comparison table includes both open-frame and silent generator structures.

Open-Frame Version

May provide:

  • Easier service access

  • Lower weight

  • Lower initial cost

  • Higher operating noise

Silent Version

May provide:

  • Reduced noise

  • Enclosed components

  • Improved weather protection

  • Higher weight

  • Different ventilation requirements

Confirm exact sound levels at a specified distance.

Wind Resistance

The lighting tower is listed with Level 8 wind resistance.

Before publication, confirm:

  • Wind-speed equivalent

  • Mast height during testing

  • Stabilizer deployment

  • Ground conditions

  • Lamp orientation

  • Test standard

  • Safety factor

Wind resistance should not be advertised without stating the operating configuration.

Stabilizing Outriggers

Four stabilizing supports are listed.

Before mast extension:

  • Position the machine on firm ground

  • Apply the wheel brake

  • Extend all stabilizers

  • Level the machine

  • Confirm safe wind conditions

Before publication, confirm stabilizer extension, ground-pad size, and maximum permitted slope.

Wheels and Mobility

The tower uses 12-inch pneumatic tyres and push-handle steering.

Confirm:

  • Wheel quantity

  • Tyre pressure

  • Parking-brake type

  • Maximum manual-moving slope

  • Towing capability

  • Total machine width

  • Ground clearance

Do not advertise trailer towing unless a certified tow hitch is included.

Electrical Controls

The lighting tower includes:

  • Main electrical switch

  • Individual lamp switches

Before publication, confirm:

  • Circuit-breaker ratings

  • Emergency stop

  • Residual-current protection

  • Grounding point

  • Overload protection

  • Output sockets

  • Voltage meter

  • Frequency meter

  • Hour meter

IP65 Protection

The listed IP65 rating may indicate:

  • Dust-tight construction

  • Resistance to low-pressure water jets

Confirm whether IP65 applies to:

  • Lamp housings

  • Electrical control panel

  • Generator enclosure

  • Cable connectors

  • Complete lighting tower

The complete machine should only carry the rating if the entire system was tested.

Dimensions and Weight

Depending on the selected configuration, dimensions are approximately:

  • 1200 × 950 × 2100 mm

  • 1200 × 950 × 2200 mm

Weight ranges from approximately:

  • 245 kg

  • 265 kg

  • 279 kg

  • 280 kg

  • 300 kg

The final listing should specify whether dimensions and weight are measured:

  • With mast lowered

  • With fuel

  • With generator

  • With lamps installed

  • With stabilizers retracted

Suitable Applications

The ANJ6150 mobile lighting tower may be suitable for:

  • Construction sites

  • Road maintenance

  • Mining and quarry operations

  • Emergency response

  • Disaster-relief work

  • Outdoor events

  • Oil and gas work sites

  • Utility repairs

  • Ports and warehouses

  • Airport perimeter work

  • Railway maintenance

  • Remote industrial locations

The selected version should match required light output, runtime, mast height, noise restrictions, fuel availability, and mobility needs.

Customization Options

Available custom options may include:

  • LED or metal-halide lamps

  • Lamp quantity

  • Lamp wattage

  • Mast height

  • Hand-cranked or hydraulic lifting

  • Gasoline or diesel engine

  • Generator size

  • Fuel-tank capacity

  • Open-frame or silent enclosure

  • Housing colour

  • Logo and branding

  • Trailer or hand-push chassis

  • Electrical outlets

  • Control panel

Each custom unit should receive a final approved technical data sheet before production.

Package Contents

Depending on the selected model, the package may include:

  • ANJ6150 mobile lighting tower

  • Lamp assemblies

  • Q235 steel telescopic mast

  • Generator set

  • Engine

  • Fuel tank

  • Electrical control panel

  • Four stabilizing supports

  • Pneumatic wheels

  • Hand-push steering handle

  • Operating tools

  • User manual

  • Maintenance documentation

Only verified included items should appear in the final listing.

Warranty

The listed warranty period is one year.

Before publication, confirm coverage for:

  • Lamp heads

  • Metal-halide ballasts

  • LED drivers

  • Engine

  • Generator

  • Mast

  • Winch or hydraulic system

  • Electrical controls

  • Fuel system

  • Wheels and brakes

  • Labour

  • Replacement parts

  • Shipping costs

Important Safety Information

Place the lighting tower on stable, level ground and fully deploy all four stabilizers before raising the mast.

Do not raise or operate the mast beyond the verified wind-speed limit. Keep the tower away from overhead electrical lines, cranes, buildings, trees, and other obstructions.

Allow metal-halide lamps to cool before handling. Hot lamps may require a delay before restarting.

Operate gasoline and diesel engines only in properly ventilated outdoor environments. Exhaust gases contain carbon monoxide.

Use trained personnel for generator maintenance, electrical repairs, mast inspection, lamp replacement, and hydraulic servicing.

Translation missing: en.general.search.loading